Palladium-catalyst technology delivering hydrocarbon-free zero air for GC-FID, environmental analyzers, and instrument baseline reference. Benchtop, rack-mount, and self-contained compressor models — plus AG OFCAS oil-free air compressors to power any external-air generator. Eliminate cylinders with continuous on-demand generation.
From ultra-compact benchtop zero air generators to multi-contaminant TOTAL systems and AG OFCAS oil-free compressors to power external-air models — the ZA Series is a complete zero and instrument air solution for any lab configuration.
Ultra-compact benchtop zero air generators. External compressed air required. Stackable with HG and NG units.
Standard 19" rack-mount zero air generators. 2U (1.5–6 L/min) and 4U (15–50 L/min) profiles. External air required.
Integrated oil-free piston compressor — plug in and generate. No compressed air infrastructure needed. 3 models.
High-capacity standalone with integrated compressor. Up to 30 L/min. Large internal tanks for peak demand buffering.
Multi-contaminant zero air — removes HC, CO, NOx, SO₂, and CO₂. For environmental reference and emission monitoring.
Standalone TOTAL purification with integrated compressor. Ultrapure dew points to −70°C. For the most demanding refs.
Multi-channel compressor version with up to 2 independent zero air outlets. For dual-instrument or backup-supply labs.
Rack-integrated format for instrument bay deployments. Stackable with HG and NG RACK generators for complete gas panels.
Oil-free piston and Scroll iQ compressors providing clean compressed air for all external-air ZA generators and NG EOLO nitrogen generators.
Ultra-compact benchtop zero air generators using palladium-catalyst technology. Removes hydrocarbons to <0.05 ppm from external compressed air. Stackable with HG Hydrogen and NG Nitrogen generators for a complete GC gas panel in one rack column. RS-485 standard.
Single GC-FID instrument supply. Ultra-thin 14 cm profile — slots into any bench. Palladium catalyst oven purification.
Mid-range flow for multiple GC-FID instruments or high-flow detectors. Larger catalyst bed for sustained high output.
Highest flow benchtop FID Air model. Ideal for multi-instrument labs or high-demand fuel-air supply applications.
ZA FID Air units share the same footprint and mounting standard as HG Hydrogen and NG RACK generators — all three can be stacked in a standard 19" instrument bay to form a complete, self-contained GC gas supply panel with zero air, hydrogen, and nitrogen from a single column.
Standard 19" rack-mount zero air generators for instrument bays. 2U profile for 1.5–6 L/min, 4U profile for 15–50 L/min. Palladium-catalyst purification, RS-485, <0.05 ppm HC. Stackable with HG and NG RACK generators for full gas panel integration.
Compact 2-unit rack profile for small-flow FID applications. Three flow configurations: 1.5, 3.0, or 6.0 L/min. Fits any 19" instrument cabinet.
High-flow 4U rack model. 50 L/min variant uses 65 cm deep chassis. For multi-instrument labs with multiple GC-FID detectors or high-demand applications.
Self-contained zero air generators with integrated 100% oil-free piston compressor and palladium catalyst oven — simply connect to power and start generating. No external compressed air required. RS-485 and RS-232 standard. Benchtop form factor.
Truly standalone — plug into wall power and start producing zero air. Built-in oil-free piston compressor. For single GC-FID without compressed air infrastructure.
Highest flow C model. Three independent flow configurations from the same chassis. RS-232 for service, RS-485 for lab automation.
High-capacity standalone zero air generators with integrated 100% oil-free compressor, internal 10 L air tank, and 5 L buffer tank — designed for continuous 24/7 operation and peak demand buffering. Up to 30 L/min from a single plug-in unit. No external air source needed.
Highest-flow C PLUS model — 30 L/min for multi-instrument FID labs or continuous high-demand supply. Internal 10 L + 5 L tanks buffer peak demand.
The ZA TOTAL goes beyond FID air — it removes not only hydrocarbons, but also CO, NOx, SO₂, and CO₂ for true zero reference air. Essential for environmental monitoring, emissions analyzers, and any instrument measuring trace atmospheric components. Exceptional dew points to −75°C on smaller models.
True zero reference air — removes 5 contaminant classes. Exceptional −75°C dew point. RS-485 standard.
Highest-flow TOTAL model. Removes HC, CO, NOx, SO₂, and CO₂ at 30 L/min for multi-analyzer environmental monitoring stations.
ZA FID Air removes hydrocarbons only (<0.05 ppm HC) — sufficient for GC-FID fuel air. ZA TOTAL additionally removes CO, NOx, SO₂, and CO₂ for true multi-contaminant zero reference air required by environmental monitors, CEMs, and atmospheric analyzers where trace gas background interference must be eliminated.
Self-contained multi-contaminant zero air generators — full TOTAL purification (HC, CO, NOx, SO₂, CO₂) with integrated oil-free compressor. No external air needed. The HP variant achieves an exceptional −70°C dew point and <0.1 ppm CO₂ for the most demanding reference applications.
Standalone TOTAL purification with built-in compressor. Plug in, power on, generate certified reference air. RS-485, RS-232, optional alarm contact.
Highest-purity ZA model. CO₂ removal to <0.1 ppm (vs 5 ppm for standard TOTAL C) and dew point to −70°C. For NIST-traceable calibration references and regulatory monitoring.
Multi-channel zero air generators with integrated compressor — providing two independent, regulated zero air outlets from a single unit. Ideal for dual-instrument labs, redundant supply, or locations requiring independent flow/pressure for two separate GC-FID systems.
Two independently regulated zero air outlets. RS-485 and RS-232. Palladium catalyst. Oil-free compressor. For dual GC-FID setups from a single generator.
Higher flow dual-channel variant. Two 3 L/min outputs independently regulated. Compact same footprint as FID Air C series.
Catalytic oxidation using a palladium-filled oven converts hydrocarbon contaminants to water and CO₂, then removes them — achieving <0.05 ppm THC reliably across the full flow range.
Multi-stage drying with molecular sieves and cooling coils achieve atmospheric dew points as low as −75°C — ensuring baseline stability for sensitive humidity-affected detectors.
C, C PLUS, TOTAL C, and TOTAL C HP models include built-in 100% oil-free piston compressors — completely standalone with no compressed air infrastructure required.
ZA FID Air and RACK series share the same footprint and rack standard as HG and NG generators — stack all three into a single instrument bay for a complete GC gas supply panel.
All models include RS-485 for lab automation and remote monitoring. C-series models add RS-232 for service. Optional alarm contacts available on TOTAL C series.
Permanent, continuous on-demand zero air at a fraction of cylinder cost. Eliminate cylinder rentals, deliveries, regulator changes, and handling risks in your lab.
From routine GC-FID flame air to regulatory-grade environmental reference standards, ZA Series generators deliver certified zero air performance for the full spectrum of analytical needs.
Primary application — oxidant gas for Flame Ionization Detectors. Zero HC background ensures detector sensitivity and baseline stability for accurate quantitation.
Zero reference gas for continuous emissions monitors (CEMs) and ambient air analyzers measuring VOCs, CO, NOx, SO₂, and ozone. ZA TOTAL removes all interferents.
Zero reference standard for span/zero calibration routines on any instrument measuring hydrocarbon or trace gas concentrations. Traceable to known zero baseline.
Clean, dry carrier and make-up gas for Electron Capture and Photoionization Detectors. Hydrocarbon-free ensures no background interference with electron-sensitive detectors.
Hydrocarbon-free purge gas for Total Organic Carbon analyzers. Zero air eliminates atmospheric HC background that would inflate TOC readings.
CO₂ and hydrocarbon-free purge for FTIR instrument optical paths. ZA TOTAL removes both HC and CO₂, eliminating absorption bands that interfere with spectra.
Zero air background for ozone, NOx, SO₂, and CO ambient monitoring stations. Regulatory-compliant zero reference for EPA Method reference equivalency programs.
Clean oxidant gas for combustion testing and calorimetry. Hydrocarbon-free air eliminates HC contribution to combustion analysis results.
Ultra-pure process air for cleanroom environments, wafer processing, and semiconductor manufacturing where trace HC contamination is critical.
Diluent gas for preparing calibration standards by dynamic dilution of certified reference gas mixtures to required concentration levels.
Compare key specifications across the ZA Series lineup to select the ideal zero air generator for your application and infrastructure.
| Model | Flow Rate | HC Content | Dew Point | Air Source | CO₂ Removal |
|---|---|---|---|---|---|
| ZA FID Air 1.5 | 1.5 L/min | <0.05 ppm | <−35°C | External | No |
| ZA FID Air 3.0 | 3.0 L/min | <0.05 ppm | <−35°C | External | No |
| ZA FID Air 6.0 | 6.0 L/min | <0.05 ppm | <−35°C | External | No |
| ZA FID Air 15.0 | 15.0 L/min | <0.05 ppm | <−35°C | External | No |
| ZA FID Air 30.0 | 30.0 L/min | <0.05 ppm | <−35°C | External | No |
| ZA RACK FID 2U (1.5–6) | 1.5–6.0 L/min | <0.05 ppm | <−35°C | External | No |
| ZA RACK FID 4U (15–50) | 15–50 L/min | <0.05 ppm | <−35°C | External | No |
| ZA FID Air C 1.5 | 1.5 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C 3.0 | 3.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C 6.0 | 6.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C PLUS 1.5 | 1.5 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C PLUS 3.0 | 3.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C PLUS 6.0 | 6.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C PLUS 15.0 | 15.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air C PLUS 30.0 | 30.0 L/min | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air MC 1.5 | 1.5 L/min ×2 | <0.05 ppm | <−30°C | Built-in | No |
| ZA FID Air MC 3.0 | 3.0 L/min ×2 | <0.05 ppm | <−30°C | Built-in | No |
| ZA TOTAL 1500 | 1.5 L/min | <0.05 ppm | <−75°C | External | <5 ppm |
| ZA TOTAL 3000 | 3.0 L/min | <0.05 ppm | <−75°C | External | <5 ppm |
| ZA TOTAL 6000 | 6.0 L/min | <0.05 ppm | <−75°C | External | <5 ppm |
| ZA TOTAL 15000 | 15.0 L/min | <0.05 ppm | <−70°C | External | <5 ppm |
| ZA TOTAL 30000 | 30.0 L/min | <0.05 ppm | <−70°C | External | <5 ppm |
| ZA TOTAL C 1.5 | 1.5 L/min | <0.05 ppm | <−60°C | Built-in | <5 ppm |
| ZA TOTAL C 3.0 | 3.0 L/min | <0.05 ppm | <−60°C | Built-in | <5 ppm |
| ZA TOTAL C 6.0 | 6.0 L/min | <0.05 ppm | <−60°C | Built-in | <5 ppm |
| ZA TOTAL C HP 1.5 | 1.5 L/min | <0.05 ppm | <−70°C | Built-in | <0.1 ppm |
| ZA TOTAL C HP 3.0 | 3.0 L/min | <0.05 ppm | <−70°C | Built-in | <0.1 ppm |
| Model | Air Flow (Max) | Max Pressure | Dew Point | Noise | Form Factor | Tank |
|---|---|---|---|---|---|---|
| AG OFCAS 35 | 35 L/min @ 101.5 psi (7 bar) | 123.2 psi (8.5 bar) | <−20°C | 58 dB(A) | Benchtop · 27×44×41 cm | 4 L |
| AG OFCAS 35 PLUS | 35 L/min @ 101.5 psi (7 bar) | — | <−20°C | <52 dB(A) | Floor · 43×75×68 cm | 10 L |
| AG OFCAS 40 | 40 L/min @ 101.5 psi (7 bar) | 145 psi (10 bar) | <−20°C | 57 dB(A) | Benchtop · 27×51×51 cm | 5 L |
| AG OFCAS 60 | 60 L/min @ 101.5 psi (7 bar) | — | <−20°C | <58 dB(A) | Floor · 44×76×68 cm | 2×10 L |
| AG OFCAS 10 RACK 4U | 10 L/min @ 43.5 psi (3 bar) | 101.5 psi (7 bar) | <−10°C | 55 dB(A) | 19" 4U · 48 cm deep | 2 L |
| AG OFCAS 40 RACK 6U | 40 L/min @ 87 psi (6 bar) | 116 psi (8 bar) | <−20°C | 65 dB(A) | 19" 6U · 41 cm deep | 4 L |
| AG OFCAS Scroll iQ 220 8 | 220 L/min (190 @ 116 psi (8 bar)) | 116 psi (8 bar) | <−20°C (with dryer) | <50 dB(A) | Floor · 59×92×73 cm | — |
| AG OFCAS Scroll iQ 220 8 BASIC | 220 L/min (220 @ 116 psi (8 bar)) | 116 psi (8 bar) | No dryer | <52 dB(A) | Floor · 59×92×73 cm | — |
| AG OFCAS Scroll iQ 200 10 | 200 L/min (170 @ 145 psi (10 bar)) | 145 psi (10 bar) | <−20°C (with dryer) | <52 dB(A) | Floor · 59×92×73 cm | — |
| AG OFCAS Scroll iQ 200 10 BASIC | 200 L/min (200 @ 145 psi (10 bar)) | 145 psi (10 bar) | No dryer | <52 dB(A) | Floor · 59×92×73 cm | — |
The AG OFCAS series provides the clean, dry compressed air source required by all external-air ZA FID, ZA TOTAL, and NG EOLO generators. Oil-free piston and scroll compressor technology, automatic water purge, and electronic pressure control — purpose-built for continuous laboratory use. Choose from benchtop piston models (35–60 L/min), 19" rack-mount profiles, or high-capacity Scroll iQ units (up to 220 L/min) for LCMS infrastructure.
Compact benchtop piston compressor. Direct replacement air source for ZA FID Air and ZA TOTAL external-air models, and NG EOLO. Optional soundproof box accessory available. Electronic pressure control with set-point hysteresis.
Quieter floor-standing variant with 10 L internal tank (vs 4 L on the 35) for smoother pressure delivery. 6 dB quieter than OFCAS 35 at <52 dB(A). Full-range 110/240 VAC model available. ¼" BSPP outlet.
Higher flow benchtop piston compressor with 145 psi (10 bar) max pressure capability. Slightly squarer footprint than the OFCAS 35 for larger instrument bench deployments. 110 VAC model available.
Highest-flow piston model — dual-compressor design with two 10 L internal tanks (total 20 L) for continuous high-demand supply. Ideal for large ZA FID Air and NG EOLO installations with multiple instruments. 110 VAC model available.
Compact 4U rack compressor for instrument bay integration alongside ZA RACK FID generators. Low 250 W power draw. Stackable with HG and NG RACK generators for complete gas panel solutions.
High-flow 6U rack compressor. Powers ZA RACK FID 4U (15–50 L/min) and NG SIRIO generators from the same instrument cabinet. Full-range 110/240 VAC model available.
Scroll technology delivers ultra-quiet operation at <50 dB(A) — the quietest OFCAS compressor. For NG CASTORE membrane and NG POLLUCE PSA nitrogen generators in LC/MS labs. Touchscreen LCD, RS-485, RS-232, Digital I/O. Energy-saving algorithm. PID pressure, ON/OFF, and normal logic operating modes. Parallel connection available for redundancy.
BASIC variant without integrated dryer — for use with an external dryer or where inlet air is already dry. Lighter (140 kg vs 150 kg) and slightly lower noise at <52 dB(A).
Higher pressure 145 psi (10 bar) variant for generators requiring elevated inlet pressure. Ideal for NG CASTORE with elevated nitrogen outlet pressure requirements. BASIC version also available.
Full-range power supply variants (115–240 VAC) — 200 8, 200 8 BASIC, 180 10, and 180 10 BASIC — for international deployments or mixed-voltage lab environments. BASIC variants omit the integrated dryer.
Match the compressor output to your generator's air inlet requirement. ZA FID Air / ZA TOTAL (external air): OFCAS 35 or 35 PLUS for 1–3 generators; OFCAS 40 or 60 for higher combined flow. ZA RACK FID: OFCAS RACK 4U (10 L/min) or 6U (40 L/min) for clean in-rack integration. NG CASTORE (membrane N₂): OFCAS Scroll iQ 220 or 200 series for the high flow rates membrane generators require. The Scroll iQ is also the quietest option at <50 dB(A).
Contact our team to discuss your zero air requirements. We'll help you select the ideal ZA Series model — whether you need a simple benchtop FID air supply or a multi-contaminant total zero air system for environmental monitoring.