The HLP Series demineralizators deliver ISO 3696 Type II and Type I purity water directly from your tap supply — eliminating bottled water costs, storage hassles, and quality inconsistencies for AAS, ICP-MS, HPLC, IC, and GC analyses.
From standard mixed-ion-exchange demineralization to advanced UV sterilization with dual purity class output — the HLP Series provides the right water quality for every analytical application.
Mixed-ion-exchange demineralization with reverse osmosis and integrated sediment-carbon-softening module. Type II purity water for routine analytical work. Acid-proof stainless steel housing.
All standard purification stages plus 254 nm UV sterilization lamp. Dual water intake points for Type II and Type I purity. Ideal for bacteria cultures, biochemical analyses, and ultra-sensitive instruments.
Multi-stage water purification using sediment filtration, carbon treatment, softening, mixed-ion-exchange demineralization, and reverse osmosis. Conductivity <0.06 µS/cm meets PN-EN ISO 3696:1999 Type II, ASTM, CLSI, and FP standards. Powered entirely by tap water pressure — no electricity needed for the water circuit.
Compact entry-level demineralizer for low-volume labs. Ideal for single-instrument setups running AAS or IC. Acid-proof stainless steel housing with LCD interface.
Mid-range capacity for multi-instrument labs. Handles daily HPLC and ICP-MS water demands with the same compact footprint and stainless steel construction.
High-throughput model for busy labs with continuous water demand. Supplies multiple instruments simultaneously. Same integrated module design ensures consistent purity.
All the purification stages of the standard HLP plus a 254 nm ultraviolet sterilization lamp for biological decontamination. Two independent water intake points deliver Type II (ISO 3696:1999, ASTM, CLSI) and Type I (ISO 3696:1999, EP) purity water. Ideal for bacteria cultures, biochemical analyses, and general-purpose research.
Entry-level UV demineralizer with dual purity class output. Compact enough for small bioanalytical labs requiring sterile Type I water alongside routine Type II supply.
Mid-capacity UV model for labs running daily biochemical assays alongside instrumental analyses. Dual intake points allow two users or instruments to draw different purity grades simultaneously.
Highest throughput UV model for high-demand research facilities. 20–22 L/h output supports continuous operation across multiple instruments, bacteria culture workflows, and general-purpose research.
Standard (p Series): Choose this for routine instrumental analysis (AAS, IC, HPLC, GC) where Type II water is sufficient. UV Series: Choose this when your workflow requires sterile Type I water — bacteria cultures, biochemical analyses, or EP-compliant applications. Both series share the same compact footprint and are powered by tap water pressure alone. Select 5, 10, or 20 based on your daily water consumption.
Every HLP demineralizer is built with laboratory-grade materials and multi-stage purification to deliver consistent, standards-compliant water day after day.
Sediment filtration, activated carbon, water softening, mixed-ion-exchange demineralization, and reverse osmosis work in sequence to remove contaminants at every level.
Output water meets PN-EN ISO 3696:1999 Type II purity, plus ASTM, CLSI, and FP pharmacopeia standards. UV models also deliver Type I purity.
Acid-proof stainless steel construction resists corrosion in demanding lab environments. Built to last with minimal maintenance requirements.
LCD interface provides real-time monitoring of conductivity, flow, and filter status. Simple, user-friendly management of all system functions.
The water circuit runs entirely on municipal tap water pressure. Electrical power is only needed for the control system and 24V water pump — consuming just 20–100W.
254 nm UV lamp eliminates bacteria and microorganisms for Type I water purity. Essential for biological and biochemical research applications.
HLP purified water supports the most demanding analytical techniques across chemistry, biology, and pharmaceutical laboratories.
Atomic absorption spectroscopy requires contaminant-free water for sample preparation, standard dilution, and blank measurements. HLP water eliminates trace metal interference.
Ultra-trace elemental analysis demands the highest purity water. HLP output minimizes background contamination for accurate parts-per-trillion measurements.
High-performance liquid chromatography mobile phase preparation requires low-conductivity water to prevent baseline noise and ghost peaks.
IC eluent preparation and sample dilution require water free of ionic contaminants. HLP conductivity <0.06 µS/cm ensures clean baselines.
Gas chromatography sample preparation and solvent-grade water for extractions. Consistent purity eliminates batch-to-batch variability.
UV-sterilized Type I water for microbiological media preparation, cell culture workflows, and sterile rinsing. 254 nm lamp ensures biological decontamination.
Enzyme assays, protein purification, and molecular biology workflows that require endotoxin-free, sterile water with documented purity compliance.
Purified production water meeting FP pharmacopeia requirements for quality control laboratories in pharmaceutical manufacturing environments.
Side-by-side specifications for every HLP demineralizer model.
| Model | Efficiency | Conductivity | Filtration | UV Lamp | Purity Class | Dimensions (W×H×D) |
|---|---|---|---|---|---|---|
| HLP 5p | 5–7 L/h | <0.06 µS/cm | 1 µm | — | Type II | 232×510×443 mm |
| HLP 10p | 10–12 L/h | <0.06 µS/cm | 1 µm | — | Type II | 232×570×478 mm |
| HLP 20p HIGH CAP | 20–22 L/h | <0.06 µS/cm | 1 µm | — | Type II | 235×570×470 mm |
| HLP 5UV | 5–7 L/h | <0.06 µS/cm | 5 µm | 254 nm | Type II + I | 235×510×470 mm |
| HLP 10UV | 10–12 L/h | <0.06 µS/cm | 5 µm | 254 nm | Type II + I | 235×570×470 mm |
| HLP 20UV HIGH CAP | 20–22 L/h | <0.06 µS/cm | 5 µm | 254 nm | Type II + I | 235×570×470 mm |
All HLP models share: acid-proof stainless steel housing, 10 L integrated tank (390 mm H × 250 mm DIA), tap water pressure powered, 230V/50Hz supply voltage, 24V water pump, 20–100W energy consumption, RS 232 connector, and purified water intake speed of 1–2 L/min at ~2 bar outlet pressure. Feed water requirements: conductivity <1200 µS/cm, pressure >3.0 bar, hardness <250 mg CaCO3/L, Fe <0.2 mg/L.
Contact our team to discuss your laboratory water requirements. We'll help you select the ideal HLP model — whether you need standard Type II demineralized water or UV-sterilized Type I water for biological research.