LNI Swissgas · HLP Series

Laboratory-grade purified water on demand

The HLP Series demineralizators deliver ISO 3696 Type II and Type I purity water directly from your tap supply — eliminating bottled water costs, storage hassles, and quality inconsistencies for AAS, ICP-MS, HPLC, IC, and GC analyses.

<0.06 µS/cm Conductivity
6 Models Available
5–22 L/h Efficiency
ISO 3696 Compliant
Choose Your Series

Two product families — standard & UV purification

From standard mixed-ion-exchange demineralization to advanced UV sterilization with dual purity class output — the HLP Series provides the right water quality for every analytical application.

💧

HLP Standard (p Series)

Mixed-ion-exchange demineralization with reverse osmosis and integrated sediment-carbon-softening module. Type II purity water for routine analytical work. Acid-proof stainless steel housing.

3 models · HLP 5p / 10p / 20p · 5–22 L/h
☀️

HLP UV (UV Series)

All standard purification stages plus 254 nm UV sterilization lamp. Dual water intake points for Type II and Type I purity. Ideal for bacteria cultures, biochemical analyses, and ultra-sensitive instruments.

3 models · HLP 5UV / 10UV / 20UV · 5–22 L/h
Standard Demineralizers

HLP Standard (p Series)

Multi-stage water purification using sediment filtration, carbon treatment, softening, mixed-ion-exchange demineralization, and reverse osmosis. Conductivity <0.06 µS/cm meets PN-EN ISO 3696:1999 Type II, ASTM, CLSI, and FP standards. Powered entirely by tap water pressure — no electricity needed for the water circuit.

HLP 5p Demineralizer
5p

HLP 5p

5–7 L/h
  • Efficiency5–7 L/h
  • Conductivity<0.06 µS/cm
  • Particle Filtration1 µm
  • Tank Capacity10 L
  • Power20–100 W
  • Size (W×H×D)232×510×443 mm

Compact entry-level demineralizer for low-volume labs. Ideal for single-instrument setups running AAS or IC. Acid-proof stainless steel housing with LCD interface.

HLP 10p Demineralizer
10p

HLP 10p

10–12 L/h
  • Efficiency10–12 L/h
  • Conductivity<0.06 µS/cm
  • Particle Filtration1 µm
  • Tank Capacity10 L
  • Power20–100 W
  • Size (W×H×D)232×570×478 mm

Mid-range capacity for multi-instrument labs. Handles daily HPLC and ICP-MS water demands with the same compact footprint and stainless steel construction.

HLP 20p Demineralizer
20p

HLP 20p

20–22 L/h
  • Efficiency20–22 L/h
  • Conductivity<0.06 µS/cm
  • Particle Filtration1 µm
  • Tank Capacity10 L
  • Power20–100 W
  • Size (W×H×D)235×570×470 mm

High-throughput model for busy labs with continuous water demand. Supplies multiple instruments simultaneously. Same integrated module design ensures consistent purity.

UV Sterilization

HLP UV Series

All the purification stages of the standard HLP plus a 254 nm ultraviolet sterilization lamp for biological decontamination. Two independent water intake points deliver Type II (ISO 3696:1999, ASTM, CLSI) and Type I (ISO 3696:1999, EP) purity water. Ideal for bacteria cultures, biochemical analyses, and general-purpose research.

HLP 5UV Demineralizer
5UV

HLP 5UV

5–7 L/h
  • Efficiency5–7 L/h
  • Conductivity<0.06 µS/cm
  • UV Lamp254 nm
  • Sediment Filtration5 µm
  • Tank Capacity10 L
  • Size (W×H×D)235×510×470 mm

Entry-level UV demineralizer with dual purity class output. Compact enough for small bioanalytical labs requiring sterile Type I water alongside routine Type II supply.

HLP 10UV Demineralizer
10UV

HLP 10UV

10–12 L/h
  • Efficiency10–12 L/h
  • Conductivity<0.06 µS/cm
  • UV Lamp254 nm
  • Sediment Filtration5 µm
  • Tank Capacity10 L
  • Size (W×H×D)235×570×470 mm

Mid-capacity UV model for labs running daily biochemical assays alongside instrumental analyses. Dual intake points allow two users or instruments to draw different purity grades simultaneously.

HLP 20UV Demineralizer
20UV

HLP 20UV

20–22 L/h
  • Efficiency20–22 L/h
  • Conductivity<0.06 µS/cm
  • UV Lamp254 nm
  • Sediment Filtration5 µm
  • Tank Capacity10 L
  • Size (W×H×D)235×570×470 mm

Highest throughput UV model for high-demand research facilities. 20–22 L/h output supports continuous operation across multiple instruments, bacteria culture workflows, and general-purpose research.

Which HLP model do I need?

Standard (p Series): Choose this for routine instrumental analysis (AAS, IC, HPLC, GC) where Type II water is sufficient. UV Series: Choose this when your workflow requires sterile Type I water — bacteria cultures, biochemical analyses, or EP-compliant applications. Both series share the same compact footprint and are powered by tap water pressure alone. Select 5, 10, or 20 based on your daily water consumption.

Why HLP Series

Engineered for laboratory reliability

Every HLP demineralizer is built with laboratory-grade materials and multi-stage purification to deliver consistent, standards-compliant water day after day.

💧

Multi-Stage Purification

Sediment filtration, activated carbon, water softening, mixed-ion-exchange demineralization, and reverse osmosis work in sequence to remove contaminants at every level.

⚖️

ISO 3696 Compliant

Output water meets PN-EN ISO 3696:1999 Type II purity, plus ASTM, CLSI, and FP pharmacopeia standards. UV models also deliver Type I purity.

🧬

Stainless Steel Housing

Acid-proof stainless steel construction resists corrosion in demanding lab environments. Built to last with minimal maintenance requirements.

💻

Microprocessor Control

LCD interface provides real-time monitoring of conductivity, flow, and filter status. Simple, user-friendly management of all system functions.

🔌

Tap Water Powered

The water circuit runs entirely on municipal tap water pressure. Electrical power is only needed for the control system and 24V water pump — consuming just 20–100W.

☀️

UV Sterilization (UV Models)

254 nm UV lamp eliminates bacteria and microorganisms for Type I water purity. Essential for biological and biochemical research applications.

Applications

Built for analytical precision

HLP purified water supports the most demanding analytical techniques across chemistry, biology, and pharmaceutical laboratories.

AAS

Atomic absorption spectroscopy requires contaminant-free water for sample preparation, standard dilution, and blank measurements. HLP water eliminates trace metal interference.

ICP-MS / ICP-OES

Ultra-trace elemental analysis demands the highest purity water. HLP output minimizes background contamination for accurate parts-per-trillion measurements.

HPLC

High-performance liquid chromatography mobile phase preparation requires low-conductivity water to prevent baseline noise and ghost peaks.

Ion Chromatography

IC eluent preparation and sample dilution require water free of ionic contaminants. HLP conductivity <0.06 µS/cm ensures clean baselines.

GC Sample Prep

Gas chromatography sample preparation and solvent-grade water for extractions. Consistent purity eliminates batch-to-batch variability.

Bacteria Cultures (UV)

UV-sterilized Type I water for microbiological media preparation, cell culture workflows, and sterile rinsing. 254 nm lamp ensures biological decontamination.

Biochemical Analysis (UV)

Enzyme assays, protein purification, and molecular biology workflows that require endotoxin-free, sterile water with documented purity compliance.

Pharmaceutical QC

Purified production water meeting FP pharmacopeia requirements for quality control laboratories in pharmaceutical manufacturing environments.

Full Comparison

All HLP models at a glance

Side-by-side specifications for every HLP demineralizer model.

Model Efficiency Conductivity Filtration UV Lamp Purity Class Dimensions (W×H×D)
HLP 5p 5–7 L/h <0.06 µS/cm 1 µm Type II 232×510×443 mm
HLP 10p 10–12 L/h <0.06 µS/cm 1 µm Type II 232×570×478 mm
HLP 20p HIGH CAP 20–22 L/h <0.06 µS/cm 1 µm Type II 235×570×470 mm
HLP 5UV 5–7 L/h <0.06 µS/cm 5 µm 254 nm Type II + I 235×510×470 mm
HLP 10UV 10–12 L/h <0.06 µS/cm 5 µm 254 nm Type II + I 235×570×470 mm
HLP 20UV HIGH CAP 20–22 L/h <0.06 µS/cm 5 µm 254 nm Type II + I 235×570×470 mm
Common specifications across all models

All HLP models share: acid-proof stainless steel housing, 10 L integrated tank (390 mm H × 250 mm DIA), tap water pressure powered, 230V/50Hz supply voltage, 24V water pump, 20–100W energy consumption, RS 232 connector, and purified water intake speed of 1–2 L/min at ~2 bar outlet pressure. Feed water requirements: conductivity <1200 µS/cm, pressure >3.0 bar, hardness <250 mg CaCO3/L, Fe <0.2 mg/L.